ASTM D924 PDF

ASTM D Standard Test Method for Dissipation Factor (or Power Factor) and Relative Permittivity (Dielectric Constant) of Electrical Insulating Liquids. Find the most up-to-date version of ASTM D at Engineering We perform testing by ASTM D on electrical insulating liquids used in cables, transformers, oil circuit breakers, and other electrical apparatus.

Author: Mozil Karan
Country: French Guiana
Language: English (Spanish)
Genre: Education
Published (Last): 1 November 2004
Pages: 164
PDF File Size: 7.72 Mb
ePub File Size: 15.71 Mb
ISBN: 585-9-40524-890-7
Downloads: 41698
Price: Free* [*Free Regsitration Required]
Uploader: Mibar

The astj is characterized by integrated structure, and integrates test cell, temperature controller, temperature sensor, dielectric loss test bridge, AC test power, standard capacitor, high resistance meter, DC high voltage source and other major components. Send your message to this supplier. Huazheng Electric Manufacturing Baoding Co. Dissipation factor or power factor may be useful as a means of quality control, and as an indication of changes in quality resulting from contamination and deterioration in service or as a result of handling.

Consult such procedures before samples are taken. Originally approved in as D — 47 T.

Provide a safety interlock on the door of the oven so that the electrical circuit supplying voltage to the test cell will be broken when the oven door is opened. Insulating materials of the molded mica-dust type, have been found to absorb solvents and therefore are not considered as satisfactory in the measurement of low loss liquids.

Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. Cleaning Test Cell No further reproductions authorized.

ASTM D924 method Transformer Oil Dielectric Loss And Tan-delta Tester

Use a perforated ceramic plate or disk to insulate the test cell from the metal ooring of dd924 oven if the ooring is not insulated from the oven. Wooden box with foam inside, 3. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use. What is the warranty for the product?

  COMPLETE BUSINESS STATISTICS AMIR D ACZEL PDF

The operation display can be pulled out as the pictures show: Replace the beaker with the remainder of the heated sample on the hot plate. Do not dry test cells made of Monel at this elevated temperature for more than 90 min as ashm will take place causing erroneous results. A low dissipation factor or power factor indicates low ac dielectric losses. We have a strong team including top qstm, skilled engineers and we have our own manufacture with high quality.

The volume of oil required when using this cell is mL. A less satisfactory method is use of a hot plate, but variations in temperature throughout the cell may lead to questionable results. However, an intermediate value of relative permittivity may sometimes be advantageous in achieving a better f924 distribution of ac electric fields between the liquid and solid insulating materials with which the liquid may be in series.

Also refer to Test Methods D for detailed discussion of terms.

ASTM D液体绝缘材料介质损耗测试法_百度文库

Replace the inner electrode. Internal standard capacitor electrode type capacitor,with electrode spacing 2mm. For optimum procedure do not exceed 20 min for this time. For decimal values up to 0. As a precaution against this eventuality, use a suitable stopper to plug this opening prior to starting the cleaning operation. In general, plated surfaces have been found less satisfactory than solid metal electrodes when testing liquids having low loss. Current edition approved Nov. Leakage across these paths has been found to produce an unsteady bridge balance on some bridges.

If the difference in the measurements of the two test specimens is equal to or less than 0. We Do Our Best for You! A number in parentheses indicates the year of last reapproval. Once receive your question, the supplier will answer you as soon as possible. For this reason, clean and dry the cell immediately prior to making the test, and strictly observe the procedures and precautions outlined in Enter between 20 to 4, characters.

  LDU FACTORIZATION PDF

ASTM D924 Large-Screen Auto Washing Insulating Oil Dielectric Loss Tester

Insulating oil dielectric loss and resistivity tester is used for measuring dielectric dissipation factor and DC resistivity of insulating oil and other insulating liquids.

Remove the inner electrode and hold it suspended in air; then decant the rinsing liquid and immediately ll the cell from the remainder of the heated specimen. Use a shielded wire or coaxial cable for connecting the guard and measuring electrodes to the bridge. However, an intermediate value of relative permittivity may sometimes be advantageous in achieving a better voltage distribution of a-c electric elds between the liquid and solid insulating materials with which the liquid may be in series.

China hair loss China weight loss equipment China vacuum fat loss machine. Caution should be taken when handling mercury and mercury containing products. HS code is ; 2. Typical questions asked about products Does this product support customization? The manner in which dissipation factor varies with frequency is determined by the nature of the dielectric losses, that is, whether they are predominantly polar or ionic, or are a combination of both types.

Wooden Box with Foam Inside. Please see the below display and the operation details: It is essential, therefore, that the procedures outlined below be closely followed. Caution should be taken when handling mercury and mercury containing products. asm