ACTARIS CORUS PTZ PDF

The Corus PTZ is a key element in the whole Actaris chain, from the meter to the billing data, because it converts the actual volume measured. For each FLUXI TZ and DELTA meters, correction according to pressure, temperature and compressibility factor (meaning the transformation in real. CORUS is an electronic volume converter dedicated to commercial and industrial applications. It converts the actual volume measured by the gas meter to.

Author: Kehn Shakagar
Country: Azerbaijan
Language: English (Spanish)
Genre: Automotive
Published (Last): 11 March 2018
Pages: 93
PDF File Size: 18.3 Mb
ePub File Size: 18.31 Mb
ISBN: 459-7-96395-729-5
Downloads: 80021
Price: Free* [*Free Regsitration Required]
Uploader: Kecage

Following the installation procedure, Corus PTZ has to be carefully closed using the four screws placed on each corner. Base volume outputs are automatically disabled as long as any metrological alarm is active.

Solenvis continue to supply meters and services to RWE nPower. Solenvis carry out an extensive meter upgrade project at Acraris University.

Once the configuration is completed and your data points are registered and subscribed to Wattics, you will receive access to your Wattics dashboard, and from then on will be able to log in to your Wattics Dashboard at http: Corus PTZ manages three pressure alarms: When the connected device initiates a communication, it has to take in account a wake up time of a few milliseconds.

CORUS_GUID_百度文库

Create your own integration Not supported yet? Pb T Z The reference pressure Pb and the reference temperature Tb must be programmed into the device. At a programmable period from 1s to 30s if the display is off same period than P and T acquisition?

  ANESTESICOS INHALATORIOS PDF

Pbase, Tbase, Gas composition according formula: Site Quicklinks Water Meters. Press OK to confirm Through communication? Bank of England select Solenvis to supply clamp-on metering.

Solenvis SL79 Itron-Corus gas volume converter – Solenvis Flowmeters

According to the European regulation, it bears the CE marking and complies with the following directives: To avoid erroneous operations, it is recommended to read the whole operating manual before putting the CORUS into operation. It operates at baud, baud, baud, baud, baud, baud. Status The event log has a capacity of events and cannot be reset.

It converts the actual volume measured by the gas meter to cogus conditions. From this screen, a long press on the ‘OK’ key launches a test of the display. The system is built in an IP65 enclosure, for wall or meter mounting. For safety reasons, it is strictly forbidden to use other modules than those specified by ‘Actaris’.

The closing time of the volume pulse outputs can also be programmed default value is ms. The fixed part includes the following data: The Octopus gateway is a Modbus data logger that comes with 6 x digital inputs, meaning that up to 6 pulses outputs can be counted, logged and communicated to Wattics dashboard.

The tamper input can be set into one of the following modes: When ccorus a alarm occurs: Program the required parameters Keyboard or communication? Request the link to download the Octopus software tool by submitting this form.

  IDENTIFICATION OF AGAROLYTIC BACTERIA PDF

The five keys allows to move into the various menus as described below.

Collateral Access

LF input pulse weight? The tamper input can be put into one of the following modes: Solenvis supply Johnson Controls with over meters. All cables are available with length of 0.

The frequency of retransmissions indicated in the table correspond to average frequency on the 2 outputs, when both channels are configured for pulses. Any attempt to open the box lets permanent visible marks on the seal or on the enclosure. Corus PTZ can be delivered with several different LF cables, in order to comply with all existing types of meter connections.

Corus PTZ is approved according the new European standard EN and it can be used for commercial and fiscal gas transactions. You may have a signal barrier in between to separate the safe zone from the hazardous zone.

Our team will get back to you shortly. The time closed of the volume pulse outputs can be programmed its default is value of ms.

The activation duration of the alarm outputs can be selected.